Fishmathix

⚙ Equipment

Sump Size & Drain-Back Volume Calculator

Check that your sump can take the water that drains down when the return pump stops.

Estimate only. Results are approximations based on the formulas explained below. Verify with your own test kits, measurements and product instructions.

What this calculator does

A sump adds water volume and hides equipment, but it has to cope with one critical moment: when the power fails, water keeps draining from the display down to the overflow teeth and siphons back through the return line. If the sump cannot hold it, the floor gets wet. This calculator estimates that drain-back volume, how far it raises the sump's water level and the highest safe running level for your sump.

How it is calculated

Drain-back volume = display length × width × drain-down depth plus the water in the return line, π × (inner diameter ÷ 2)² × line length. The water-level rise in the return section is the drain-back volume divided by the sump's footprint. The maximum safe running level is the sump height minus 2.5 cm of freeboard minus that rise. The 20–30 % of display volume guideline is a common starting point for choosing sump size.

Worked example

A 120 × 50 cm display that drains 2 cm before the overflow stops sends back 12 liters, plus 0.5 liters from a 1.5 m return line with a 20 mm bore – 12.5 liters in total. In an 80 × 40 cm sump that raises the level by 3.9 cm, so with a 40 cm tall sump the running level must stay below about 33.6 cm.

Inputs at a glance

  • Display volume – in liters, US gallons or UK gallons, example 400 L
  • Display length – in cm or inches, example 120 cm
  • Display width – in cm or inches, example 50 cm
  • Drain-down depth in display – in cm or inches, example 2 cm
  • Return line length – in cm or inches, example 150 cm
  • Return line inner diameter – in millimeters or inches, example 20 mm
  • Sump length – in cm or inches, example 80 cm
  • Sump width – in cm or inches, example 40 cm
  • Sump height – in cm or inches, example 40 cm

Practical tips

  • Drill a small anti-siphon hole in the return nozzle just below the water surface to limit back-siphoning.
  • Test it: switch off the return pump with the system running and mark the sump level it reaches.
  • Leave space in the sump stand for an auto top-off reservoir and maintenance access.

FAQ

How do I find the drain-down depth?

It is the distance from the running water level to the bottom of the overflow teeth or weir, typically 1–3 cm.

Why is a bigger sump not always better?

It must fit under the tank with room to work. A well-planned medium sump with safe levels beats a huge sump you cannot reach.