What this calculator does
The drain is the one part of a sump system that must never be undersized: if the return pump pushes more water than the drain can take, the display overflows. This calculator suggests the smallest standard pipe size for your flow, both for quiet gravity drains such as Durso standpipes, which run partly full, and for full-siphon main drains used in Herbie and BeanAnimal overflows.
How it is calculated
Drain capacity is estimated as the pipe's internal cross-section times a practical mean water velocity: about 1.13 m/s for gravity drains that run partly full and about 2.26 m/s for a full siphon. With schedule 40 inner diameters, this gives the familiar rule-of-thumb capacities of roughly 600 US gph for a 1-inch gravity drain and about 1,400 gph for 1½ inch. A safety margin (25 % by default) is added to your flow before choosing the size.
Worked example
With 2,000 L/h through the overflow and a 25 % margin, the design flow is 2,500 L/h. A 1-inch gravity drain handles about 2,260 L/h – not enough – so a 1¼-inch drain (about 3,900 L/h) is the right choice. As a full-siphon main drain, ¾ inch would suffice, backed up by an emergency drain.
Inputs at a glance
- Flow through the overflow – in liters per hour or US gallons per hour, example 2000 L/h
- Drain type – choose from: Gravity / Durso style (quiet, not full); Full siphon main drain (Herbie / BeanAnimal)
- Safety margin – in %, example 25
Practical tips
- Always fit an emergency drain at least as large as the main drain, with its inlet slightly higher.
- Real capacity depends on the standpipe design, drop height and air entrainment; treat these numbers as guidance and test with water.
- Bigger drains are quieter and safer – when in doubt, go one size up.
FAQ
Why are siphon drains rated so much higher?
A full siphon pulls water with the whole drop height behind it, while a gravity drain runs partly full and mixed with air.
Should I size by the pump's label flow?
Use the flow the pump actually delivers at your head height – or the label figure if you want the most conservative design.